ZCode-CCEF | |
---|---|
Applications | Suitable for small and poorly aligned guard doors, sliding guards or protective covers |
Certified according to | ISO 13849-1; EN 62061, EN ISO 14119; EN 60204-1; EN 60947-5-3; UL508 |
Approvals | CE, TUV, UL |
Supply Voltage | DC 24 V; +/- 15 %, max. 50 mA |
Number of outputs | 2 contactless safety outputs,1 auxiliary outputs |
Contact rating (safe- & auxiliary outputs) | DC 24 V; max. 200 mA; short-circuit proof |
Minimum load current | DC 24 V; 1 mA |
Switching distance recommented, maximum | 5 mm, 10 mm close / 22 mm open |
Base material | Stainless Steel 316 |
Protection | IP67, IP69K (only Stainless Steel) |
Ambient temperature | -25 °C to +105 °C |
PL; Kat.; SILCL (EN ISO 13849-1; EN /IEC 62061) | PL e; Kat.4; SILCL3* |
Vibration-, shock resistance | 10-55 Hz / 1 mm, 1 ms / 30 g |
Weight, dimensions | 300 g, 83 x 20,6 x 17 mm |
Order No. with M12 connector, inclusive actuator | 940178 |
Zander Aachen ZCode-CCEF Coded Stainless Steel Safety Switch
Zander Aachen ZCode-CCEF Coded Stainless Steel Safety Switch
代码: ZCode-CCEF
品牌: Zander Aachen
All safety switches of the ZCode series operate in a non-contact manner via an encoded magnet system with a large switching distance and high tolerance against offset to the safety door. These can be actuated only with the actuator included in the scope of supply. The switching status is indicated by a LED.
The safety relays are completely dust- and waterproof (IP 69K). The difference lies in different housing variants. For example, type ZCode-CCEF has a stainless steel housing for high temperature requirements or for high chemical resistance to environmental influences.
Zander Aachen 资料表
国家和语言 | 文件名 | 下载链接 |
United States (English) | Zander-Aachen-EN_42085.pdf | 下载 |
请求报价