Fip F6.63.10 Flowmeter
Fip F6.63.10 Flowmeter
Código: F6.63.10
Marca: FIP Italy
General
• Pipe Size Range: DN15 to DN600 (0.5” to 24”) Please refer to Installation
Fittings section for more details
• Flow Rate Range: 0.15 to 8 m/s (0.5 to 25 ft./s)
• Linearity: ± 0.75 % of full scale
• Repeatability: ± 0.5 % of full scale
• Minimum Reynolds Number Required: 4500
• Enclosure: IP68 or IP65
• Wetted Materials:
- sensor Body: CPVC, PVDF, 316L SS
- o-rings: EPDM or FPM
- rotor: ECTFE (Halar®)
- shaft: Ceramic (Al2
O3
)/316L SS (only for metal sensors)
FIP Italy Datasheets