Helmholz 700-159-3MB01 PN/ModbusTCP Coupler (inkl. Quickstart Guide)
Helmholz 700-159-3MB01 PN/ModbusTCP Coupler (inkl. Quickstart Guide)
코드: 700-159-3MB01
브랜드: Helmholz
Simple and uncomplicated connection of a PROFINET network with a ModbusTCP network is possible with the PN/ModbusTCP Coupler. The PN/ModbusTCP Coupler enables data transmission between a PROFINET controller and ModbusTCP participants. Received input data on one of the network sides is made available as output data to the other network side. The IO data transfer takes place live and as quickly as pos-sible without additional handling blocks.
The maximum size of the transmitted data is 1024 bytes of input/output data. Up to 300 slots for IO modules are available. The integration into the PLC engineering tool is made possible by a GSDML file; special configuration software isn’t necessary.
In addition to the PROFINET / ModbusTCP communication, the PN/ModbusTCP Coupler also makes an MQTT Publisher available on both network sides. In this way, the values exchanged via the gateway can also be distributed via MQTT to visualization or operating data recording systems.
General information | ||
---|---|---|
Order number | 700-159-3MB01 | |
Article name | PN/ModbusTCP Coupler | |
Scope of delivery | PN/ModbusTCP Coupler incl. Quick Start Guide | |
Dimensions (DxWxH) | 35 x 58 x 72 mm | |
Weight | Approx. 135 g | |
PROFINET interface | ||
Number | 1 with 2 ports | |
Protocol | PROFINET IO as defined in IEC 61158-6-10 | |
Transmission rate | 100 Mbps full duplex | |
I/O image size | max. 1024 bytes of input and output data | |
Connection | 2 x RJ45 | |
integrated switch | Yes | |
Features | Media redundancy (MRP), automatic addressing, topology detection (LLDP, DCP), diagnosis alarms | |
ModbusTCP interface | ||
Number | 1 with 2 ports | |
Protocol | ModbusTCP server | |
Transmission rate | 10/100 Mbps full duplex | |
I/O image size | 65536 coil bits, 65536 discrete input bits, 65536 input register, 65536 holding register | |
Connection | 2x RJ45 | |
integrated switch | Yes | |
Supports Modbus function codes | 1, 2, 3, 4, 5, 6, 15, 22, 23 | |
Status indicator | 9 LEDs function status, 8 LEDs Ethernet status | |
Voltage supply | ||
Voltage supply | 24 V DC (18 - 28 V DC) | |
Current draw | max. 210 mA | |
Ambient conditions | ||
Ambient temperature | 0 °C to 60 °C | |
Transport and storage temperature | -20 °C to 80 °C | |
Protection rating | IP 20 | |
Certifications | CE | |
CE | ||
RoHS | Yes | |
REACH | Yes |