Pavone Weighing Module MASTERMOUNT

  • Pavone Weighing Module MASTERMOUNT

Pavone Weighing Module MASTERMOUNT

Code: MASTERMOUNT
Marke: Pavone

Rated Load (RL): 2, 5, 10, 15, 20, 30 t
Combined error: < ±0.03 % RL
Repeatability: < ± 0.015 % RL
Safe overload: 150 % RL
Ultimate overload: 300 % RL
Safe sideload: 100 % RL
Ultimate sideload: 100 % RL
Compensated Temperature: -10 ÷ +40 °C
Temperature range: -50 ÷ +80 °C
Temperature effect on zero balance: < ±0.002 % RO/°C
Temperature effect on output: < ±0.0012 % of output/°C
Rated output RO: 2.0 mV/V ± 0.25 %
Zero balance: ±2 % RO
Insulation resistance: > 500 M Ohm @ 100 Vdc
Input resistance: 785 ±20 Ohm
Output resistance: 700 ±5 Ohm
Recommended input: 10 V
Maximum supply voltage: 18 V