Pavone PSCC0301 SPI OFF-CENTER 100KG
Pavone PSCC0301 SPI OFF-CENTER 100KG
Code: PSCC0301
Marke: Pavone
The off center load cell SPI, built in stainless steel, is robust and precise and is equipped with a 6-meter shielded 6-conductor cable for the electrical connection. The single point cell SPI is ideal for large single-cell platforms and guarantees accuracy in any position the object is loaded. The SPI cell is used in the food packaging sector and for the construction of single-cell scales.
Technical Specifications
| Rated load RL: 10, 30, 50, 100, 200 Kg |
| Combined error: < ±0.03 % RO |
| Repeatability: < ±0.02 % RO |
| Creep (30 minutes): ±0.03 % RO |
| Safe overload: 150 % RL |
| Ultimate overload: 300 % RL |
| Material: Stainless steel AISI 420 |
| Degree of protection: IP67 |
| Deflection: 0.5 mm |
| Compensated Temperature: -10 ÷ +40 °C |
| Temperature range: -20 ÷ +60 °C |
| Temperature effect on zero balance: < ±0.0025 % RO/°C |
| Temperature effect on output: < ±0.0025 % RO/°C |
| Rated output RO: 2 mV/V ±10 % |
| Zero balance: ±1 % RO |
| Insulation resistance: > 2000 MOhm |
| Input resistance: 385 ±30 Ohm |
| Output resistance: 350 Ohm ±3 |
| Recommended input: 5 ÷ 12 Vdc/ac |
Pavone Datenblätter
| Land Und Sprache | Dateinamen | Link Herunterladen |
| Technical_Specifications_Pavone_Systems_dat400_ab4429_77453.pdf | Downloaden | |
| Technical_Specifications_Pavone_Systems_dat500_4f7480_64370.pdf | Downloaden | |
| Technical_Specifications_Pavone_Systems_dat-500-analog_efec3b_78468.pdf | Downloaden | |
| Technical_Specifications_Pavone_Systems_mc302_43103b_19246.pdf | Downloaden | |
| Technical_Specifications_Pavone_Systems_mct-1303-batch_081be9_91178.pdf | Downloaden | |
| Technical_Specifications_Pavone_Systems_tester1006_9b8a5a_88792.pdf | Downloaden |
Vertrieb kontaktieren
Sie können uns jeder Zeit unter der Telefonnummer +49 9174 593 8670 erreichen oder per e-Mail an info@kraftindustrie.de.
Kontakt & Support
Fordern Sie ein Angebot an