Pavone Atex and Stainless Steel MCT S 1302 (ATEX 2,22)
Pavone Atex and Stainless Steel MCT S 1302 (ATEX 2,22)
Code: MCT S 1302
Marke: Pavone
Legal for Trade: certification available on request |
Measuring range: -3.9 ÷ +3.9 mV/V |
Input sensitivity: 0.02 µV/count |
Full scale non-Linearity: < 0.01 % |
Gain drift: < 0.001 % full scale/°C |
Display: graphic LCD (240x128 pixel) |
A/D Converter: 24 bit; internal resolution up to 16.000.000 |
Trasducer input voltage: 5 Vdc (max 8 load cells - 350 Ohm) |
Frequency signal acquisition: 12 ÷ 1000 Hz |
Visible resolution (in divisions): 999999 |
Divisions value (adjustable): x1, x2, x5, x10, x20, x50; 4 decimal points |
Temperature range: -10 ÷ +50°C (max umidity 85% without condensation) |
Storage temperature: -20 ÷ +70°C |
Filter: 0.1 ÷ 250 Hz |
Logic output: 6 opto-isolated; max 24 Vdc/100mA each |
Logic input: 6 optically isolated 24 Vdc PNP (external power supply) |
Additional I/O: up to 4 external modules with 4 in/8-out each (16 in/32 out, total) by independent RS485 |
Serial port: 1 USB device + 1 RS232C + 1 RS485/Fieldbus |
Analog optional output: optoisolated 16-Bit Voltage: 0 ÷5/10 V (R min10 K Ohm), Current: 0/4 ÷ 20 mA (R max 300 Ohm) |
Analog output Non-Linearity: < 0,02 % |
Temperature drift analog output: 0,001 % FS/°C |
Power supply: 18 ÷ 30 Vdc - Power consumption 5 W. Optional 115/230 Vac |
Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard from USB |
Data storage: 64 Kbytes expandable up to 1024 Kbytes |
Regulatory compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety, EN45501 for metrology |
Fieldbus: Ethernet 10/100 with protocols TCP, MODUBUS/TCP, UDP, IP, ICMP, ARP; Profinet; Ethernet/IP; ETHERCAT |
Pavone Datenblätter
Land Und Sprache | Dateinamen | Link Herunterladen |
United States (English) | Technical_Specifications_Pavone_Systems_dat400_ab4429_77453.pdf | Downloaden |
United States (English) | Technical_Specifications_Pavone_Systems_dat500_4f7480_64370.pdf | Downloaden |
United States (English) | Technical_Specifications_Pavone_Systems_dat-500-analog_efec3b_78468.pdf | Downloaden |
United States (English) | Technical_Specifications_Pavone_Systems_mc302_43103b_19246.pdf | Downloaden |
United States (English) | Technical_Specifications_Pavone_Systems_mct-1303-batch_081be9_91178.pdf | Downloaden |
United States (English) | Technical_Specifications_Pavone_Systems_tester1006_9b8a5a_88792.pdf | Downloaden |
Vertrieb kontaktieren
Sie können uns jeder Zeit unter der Telefonnummer +49 9174 593 8670 erreichen oder per e-Mail an info@kraftindustrie.de.
Kontakt & Support
Fordern Sie ein Angebot an